Academy
Spot leak detector vs flow measurement
A new technical article comparing the architectures.
Read the article
Pre-launchAQUA Contra BASIC · Sign-ups from 01-01-2027 to 15-02-2027Sign up
Home/Systems/B2C: AQUA Contra/DIY
AQUA Contra descriptionAQUA Contra DIYAQUA Contra BASIC
B2C
AQUA Contra DIY
Kit for self-assembly and installation.
In accordance with the operating and maintenance manual, installation is carried out by a plumber running an active business (sole trader) and an electrician holding SEP qualifications up to 1 kV (E/D).
Installation and assembly by unqualified persons is not permitted.
Order via the form
Launch: April 2027
Delivery within 7 days
Price
Technical specifications View product Technical specification (PDF)
≥ 1 l/minFlow detection threshold
35 LGuard mode limit
3.0–4.5 barReference operating pressure
NOSolenoid valve: fail-safe, normally open
01
Measures.
The pulse water meter registers every flow above 1 l/min.
02
Counts.
Flow analysis is based on the density of pulses generated by the flow meter. AQUA Contra uses a fixed dynamic counter threshold of 35 litres.
The analysis boundary, however, shifts dynamically and depends on detecting an expected break in flow lasting at least 15 seconds. Once this occurs, the counter is reset and the next water draw session starts from zero.
As a result, each flow cycle is analysed independently, making it possible to reliably distinguish normal use of the installation from flows typical of a failure or leak.
03
Shuts off.
The system triggers the EZ-OFF lock based on two criteria:
the volume counter limit is exceeded — the volume of water is greater than the declared 35 l,
the pulse density associated with rapid flow is exceeded — the system locks if flow Q is greater than the declared Hose Threshold,
Flood probe
Sub-threshold protection (< 1 l/min) when the probe contacts come into contact with liquid.
Operating modes
Protection logic.
03
Guard
Fixed dynamic counter threshold of 35 L; counter reset after at least 15 s without flow. The Hose Threshold is active in parallel.
35 L → EZ OFF
Pause
A timer that temporarily suspends the volume limits — for everyday household tasks.
40 min
Workshop
The system allows flood protection to be temporarily disabled for 180 minutes. When this period ends, protection is restored automatically. This lets you safely carry out workshop and cleaning jobs that use water.
180 min
Parameters
Technical data.
Full technical, environmental and installation conditions are in the downloadable document. Reading it is a prerequisite for placing an order.
Technical specification and operating conditionsPDF · 8 chapters
Terms of salePDF · in preparation
Installation manual (operating and maintenance manual)PDF
Flow detection threshold≥ 1 l/min
Guard mode limit35 L
Reference operating pressure3.0–4.5 bar
Solenoid valve: fail-safe, normally openNO
Industrial controllerPLC
Flood probe (+30% effectiveness)Option
Service bypass, sealedRequired
Controller panel
System status on the display.
04
In normal operation (no faults), the system status is shown on the LOGO! idle screen named “STAN SYSTEMU” (system status). Alarm states have dedicated screens with messages that are also visible on the web server. The web server mirrors the LOGO! screen 1:1.
System status — Guard mode
System status — Guard mode
Q = 11.52 — actual flow rate [l/min]; the reading corresponds, for example, to a shower in use
V — water counter [L]: 22.75 is the actual volume of water drawn
Ez-1 ON — solenoid valve open (OFF — flow blocked)
Pauza 00:00 — pause inactive, Guard mode active
System status — Pause
System status — Pause
Q = 12.64 — flow [l/min], e.g. shower running
V = 0.00 — in Pause mode the volume counter is disabled and water flows without a limit
Ez-1 ON — solenoid valve open
Pauza 38:46 — pause timer running, counting down to 00:00
Web server — EZ-1 lock
Web server — EZ-1 lock
Deterministic protection
for your water system.
Biuro Inżynierskie Automatyki, Koszalin
+48 000 000 000
kontakt@h-coreplc.pl
Systems
AQUA Contra — overview
AQUA Contra DIY
AQUA Contra BASIC
H-corePLC® — overview
H-corePLC® szychta
H-corePLC® office
PLC2 for risers
Academy
State of the art
Case study
Flow vs spot leak detector
FAQ
About us
Our history
Our mission
Why us
Service
Partnership
Book a presentation
Property developers
Wholesalers
Design offices
Installers
Terms of sale
PDF · version 1.0
Technical, environmental and installation requirements
PDF · H-core technical specification
Privacy policy
GDPR · page
H-corePLC®
© 2026 H-corePLC® & AQUA Contra. All rights reserved.Terms · Privacy policy · Cookies
Pre-launchSign-ups 01.01–15.02.2027Sign up
Start/Systems/DIY
B2C
AQUA Contra DIY
Kit for self-assembly and installation.
In accordance with the operating and maintenance manual, installation is carried out by a plumber running an active business (sole trader) and an electrician holding SEP qualifications up to 1 kV (E/D).
Installation and assembly by unqualified persons is not permitted.
Launch: April 2027
Delivery within 7 days
Price
≥ 1 l/minFlow detection threshold
35 LGuard mode limit
3.0–4.5 barReference operating pressure
NOSolenoid valve: fail-safe, normally open
01AQUA Contra description
02AQUA Contra DIY
03AQUA Contra BASIC
How it works01
Three steps. No interpretation.
01
Measures.
The pulse water meter registers every flow above 1 l/min.
02
Counts.
Flow analysis is based on the density of pulses generated by the flow meter. AQUA Contra uses a fixed dynamic counter threshold of 35 litres.
The analysis boundary, however, shifts dynamically and depends on detecting an expected break in flow lasting at least 15 seconds. Once this occurs, the counter is reset and the next water draw session starts from zero.
As a result, each flow cycle is analysed independently, making it possible to reliably distinguish normal use of the installation from flows typical of a failure or leak.
03
Shuts off.
The system triggers the EZ-OFF lock based on two criteria:
the volume counter limit is exceeded — the volume of water is greater than the declared 35 l,
the pulse density associated with rapid flow is exceeded — the system locks if flow Q is greater than the declared Hose Threshold,
Flood probeSub-threshold protection (< 1 l/min) when the probe contacts come into contact with liquid.
Operating modes02
Protection logic.
Guard
35 L → EZ OFF
Fixed dynamic counter threshold of 35 L; counter reset after at least 15 s without flow. The Hose Threshold is active in parallel.
Pause
40 min
A timer that temporarily suspends the volume limits — for everyday household tasks.
Workshop
180 min
The system allows flood protection to be temporarily disabled for 180 minutes. When this period ends, protection is restored automatically. This lets you safely carry out workshop and cleaning jobs that use water.
Parameters03
Technical data.
Flow detection threshold≥ 1 l/min
Guard mode limit35 L
Reference operating pressure3.0–4.5 bar
Solenoid valve: fail-safe, normally openNO
Industrial controllerPLC
Flood probe (+30% effectiveness)Option
Service bypass, sealedRequired
Technical specificationPDF
Terms of salePDF
Installation manual (operating and maintenance manual)PDF
Controller panel04
System status on the display.
In normal operation (no faults), the system status is shown on the LOGO! idle screen named “STAN SYSTEMU” (system status). Alarm states have dedicated screens with messages that are also visible on the web server. The web server mirrors the LOGO! screen 1:1.
System status — Guard modeSystem status — Guard mode
Q = 11.52 — actual flow rate [l/min]; the reading corresponds, for example, to a shower in use
V — water counter [L]: 22.75 is the actual volume of water drawn
Ez-1 ON — solenoid valve open (OFF — flow blocked)
Pauza 00:00 — pause inactive, Guard mode active
System status — PauseSystem status — Pause
Q = 12.64 — flow [l/min], e.g. shower running
V = 0.00 — in Pause mode the volume counter is disabled and water flows without a limit
Ez-1 ON — solenoid valve open
Pauza 38:46 — pause timer running, counting down to 00:00
Web server — EZ-1 lockWeb server — EZ-1 lock
Deterministic protection
for your water system.
+48 000 000 000
kontakt@h-coreplc.pl
Koszalin
Systems
AQUA Contra — overview
AQUA Contra DIY
AQUA Contra BASIC
H-corePLC® — overview
H-corePLC® szychta
H-corePLC® office
PLC2 for risers
Academy
State of the art
Case study
Flow vs spot leak detector
FAQ
About us
Our history
Our mission
Why us
Service
Partnership
Book a presentation
Property developers
Wholesalers
Design offices
Installers
Terms of salePDF · version 1.0
Technical requirementsPDF · H-core specification
Privacy policyGDPR
H-corePLC®
© 2026 H-corePLC® & AQUA Contra
Terms · Privacy policy · Cookies
LaunchApril 2027
View product