Home/Documents/Technical requirements
Document · version 11.2026
Technical specification and operating conditions of the system
Technical, environmental and installation conditions for the H-corePLC® & AQUA CONTRA systems. Reading and accepting this document is a condition of placing an order.
Download PDF Open for printing PDF · 10 chapters · to download and print

01Purpose and scope of protection

The H-corePLC® & AQUA CONTRA system is a technical protective barrier designed to minimise the consequences of plumbing failures within the declared technical parameters. The system does not guarantee the complete elimination of damage, but limits its extent by automatically shutting off the water supply (EZ OFF) once a flow anomaly is detected.

02Detection parameters and protected range

The system's effectiveness is based on continuous monitoring of dynamic flow:

  • Monitored range: the system monitors flow rates from 1 l/min upwards. This is the system's minimum meter-based detection threshold.
  • Unprotected range: any flow rate below 1 l/min (e.g. drip leaks, micro-leaks, so-called “sweating” of the installation) is regarded as neglect of building maintenance and is not covered by the system's protection.

03Role of the leak probe and installation guidelines

A spot leak probe (sensor) complements the system and increases protection effectiveness by approximately 30%. It can only respond in the sub-threshold range (< 1 l/min) when its contacts come into direct contact with liquid. This requires the probe to be placed precisely in the path of gravity-driven water run-off.

Correct positioning of the probe is a prerequisite for sub-threshold protection. The probe and its electrodes must be installed in accordance with the following guidelines:

  • Floor mounting: the probe electrodes should be 2–3 mm above floor level, at the lowest point of the wet area.
  • Installation in a floor drain (developer stage): when installed in a floor drain, the probe must be placed in its upper section. This prevents false alarms (fault states) being triggered by normal water run-off during everyday use (e.g. washing the floor, accidental splashes).
  • Location: the probe's position in the room should be determined empirically by identifying the path of gravity-driven water run-off. The probe must allow its contacts to touch the liquid directly with minimal water build-up.
  • Clear drains and maintenance: correct operation requires all drainage points to be kept fully clear. Water build-up caused by a blocked or clogged drain that triggers a fault state and water shut-off is regarded as neglect of maintenance, not a system defect.

04Exclusions of technical liability

The manufacturer accepts no liability for damage resulting from:

  • Sub-threshold leaks (below 1 l/min) whose nature prevented detection by the flow meter or by physical contact of the liquid with the probe/sensor.
  • Incorrect installation and positioning of the probe/sensor, its accidental or deliberate displacement (e.g. kicked or moved) by third parties, or the stream of water bypassing the probe/sensor (e.g. due to an uneven floor).
  • Mechanical jamming of the solenoid valve during its closing attempt (EZ-OFF) due to contaminants in the medium (e.g. sand, scale, limescale deposits), as well as damage to the solenoid valve control circuit (short circuit or open circuit) preventing it from being actuated correctly, caused e.g. by rodent activity or other mechanical factors.
  • Loss of AC power — the device operates in Fail-Safe NO (normally open) logic, which means the valve remains open in the event of a power failure. In critical or higher-risk buildings, the investor is obliged to provide an uninterruptible power supply (UPS) at their own expense.
  • Mechanical and electrical damage to the components of the RE control cabinet, as well as to the signal and power circuits connected to it.
  • Damage caused by electrical surges. The device's supply circuit must be fed from a main distribution board equipped with fully functional surge protection.
  • Interruptions in the building's protection during service or maintenance work. While system components are being removed, calibrated or repaired, water supply to the building is maintained by manually opening the service bypass. Any flood damage occurring while the system is disconnected and the building is supplied through an active bypass is not the manufacturer's responsibility.

05Risk management: leaks while Pause mode is active (Szychta / Domestic-Pause)

Hazard description: while Pause mode is active, the water volume counter is disabled by the system. During this time, protection relies solely on the dynamic flow threshold (detection of a main pipe burst) and the flood sensors.

If a connection hose starts leaking or bursts within this time window (e.g. while showering or doing household chores) and the leak produces a flow lower than the set dynamic threshold, the H-corePLC® & AQUA CONTRA system will not shut off the water supply on the basis of flow measurement.

Countermeasures and recommendations for the user:

  • Install flood sensors at critical points. During Pause, the only element capable of detecting a low-rate leak is a physical flood sensor (probe). Sensors should be placed at strategic points prone to failure (including under the shower/bath, next to washing machines, dishwashers, washbasins and in service shafts).
  • Awareness of limitations without a sensor. If there is no flood sensor at the point of failure, or it is incorrectly positioned, the leak will not be recognised by the system until Pause mode ends automatically and the system returns to Guard mode.
Pause mode blind spot. While Pause (Szychta) is active, the only and final protective barrier for the premises at flows below the dynamic threshold is the flood probe (sensor). This is a key technological area of risk management which the customer is strictly obliged to read and accept before purchasing the device.

06Installation and technical acceptance conditions

For the system to be deemed operational and covered by the warranty, the following are required:

  • Correct installation of the plumbing components according to the diagram (EZ solenoid valve, water meter, strainer, non-return valve, probe/sensor).
  • Construction and correct connection into the installation of a parallel service bypass, fitted with a manual shut-off valve sealed in the closed position.
  • Correct installation of the control cabinet (RE distribution board).
  • Completion of system acceptance tests with a positive result.
  • Signing of the commissioning and handover report confirming that the system operates in accordance with the operating and maintenance manual (DTR).

07Operational maintenance and service bypass

To ensure uninterrupted operation of the building (water supply) during maintenance work, component failures or service interruptions of the H-corePLC® system, the installation must be fitted with a hydraulic service bypass.

  • Operating status: during normal system operation, the manual bypass valve must always remain closed (securing it with a service seal is recommended).
  • Service procedure: opening the bypass and isolating the main line of the H-corePLC® & AQUA CONTRA system is permitted only for the duration of service procedures.
  • Risk awareness: the client/investor acknowledges that while the service bypass is open, the building is left entirely without the protection of the H-corePLC® & AQUA CONTRA system. Responsibility for supervising the installation during this period lies entirely with the technical staff or the building's user.

08Reference operating conditions (pressure)

The system's reference operating range is an installation working pressure of 3.0 to 4.5 bar. The client acknowledges that a drop in pipe pressure below 3.0 bar may prevent an emergency leak (e.g. a burst hose) from reaching the set flow threshold. This directly results in a longer system response time or a complete failure to detect the anomaly.

09Required water line equipment

To ensure reference operating conditions for the system, the water line must be fitted with a non-return valve and a strainer, installed upstream of the water meter and solenoid valve.

Failure to fit the above components in the water line releases the manufacturer from liability for the EZ solenoid valve failing to operate (not physically closing) when the system issues the EZ OFF signal (close solenoid valve).

10Required environmental conditions

Environmental conditions and location: the control cabinet (RE) must be installed in dry rooms, free from condensation, with a relative humidity of max. 90%. The RE must be protected from direct sunlight.

11Sub-threshold flow characteristics

Where the flow caused by a hose failure is below the dynamic detection threshold, the system protects the premises by means of the volume counter (V) and the leak probe.

For this reason, it is essential to optimise the volume threshold (V) so that this limit remains safe and acceptable in emergency conditions. Equally important is the correct positioning of the probe at the lowest point of water run-off, to ensure physical detection of the hazard before the total water volume limit is exceeded.

Deterministic protection
for your water system.
Biuro Inżynierskie Automatyki, Koszalin
+48 000 000 000
kontakt@h-coreplc.pl
Systems
AQUA Contra — overview
AQUA Contra DIY
AQUA Contra BASIC
H-corePLC® — overview
H-corePLC® szychta
H-corePLC® office
PLC2 for risers
Academy
State of the art
Case study
Flow vs spot leak detector
FAQ
About us
Our history
Our mission
Why us
Service
Partnership
Book a presentation
Property developers
Wholesalers
Design offices
Installers
Terms of sale
PDF · version 1.0
Technical, environmental and installation requirements
PDF · H-core technical specification
Privacy policy
GDPR · page
H-corePLC®
© 2026 H-corePLC® & AQUA Contra. All rights reserved.Terms · Privacy policy · Cookies
Pre-launchSign-ups 01.01–15.02.2027Sign up
Start/Documents/Technical requirements
Document · 11.2026
Technical specification and operating conditions of the system
Technical, environmental and installation conditions for the H-corePLC® & AQUA CONTRA systems. Reading and accepting this document is a condition of placing an order.

01Purpose and scope of protection

The H-corePLC® & AQUA CONTRA system is a technical protective barrier designed to minimise the consequences of plumbing failures within the declared technical parameters. The system does not guarantee the complete elimination of damage, but limits its extent by automatically shutting off the water supply (EZ OFF) once a flow anomaly is detected.

02Detection parameters and protected range

The system's effectiveness is based on continuous monitoring of dynamic flow:

  • Monitored range: the system monitors flow rates from 1 l/min upwards. This is the system's minimum meter-based detection threshold.
  • Unprotected range: any flow rate below 1 l/min (e.g. drip leaks, micro-leaks, so-called “sweating” of the installation) is regarded as neglect of building maintenance and is not covered by the system's protection.

03Role of the leak probe and installation guidelines

A spot leak probe (sensor) complements the system and increases protection effectiveness by approximately 30%. It can only respond in the sub-threshold range (< 1 l/min) when its contacts come into direct contact with liquid. This requires the probe to be placed precisely in the path of gravity-driven water run-off.

Correct positioning of the probe is a prerequisite for sub-threshold protection. The probe and its electrodes must be installed in accordance with the following guidelines:

  • Floor mounting: the probe electrodes should be 2–3 mm above floor level, at the lowest point of the wet area.
  • Installation in a floor drain (developer stage): when installed in a floor drain, the probe must be placed in its upper section. This prevents false alarms (fault states) being triggered by normal water run-off during everyday use (e.g. washing the floor, accidental splashes).
  • Location: the probe's position in the room should be determined empirically by identifying the path of gravity-driven water run-off. The probe must allow its contacts to touch the liquid directly with minimal water build-up.
  • Clear drains and maintenance: correct operation requires all drainage points to be kept fully clear. Water build-up caused by a blocked or clogged drain that triggers a fault state and water shut-off is regarded as neglect of maintenance, not a system defect.

04Exclusions of technical liability

The manufacturer accepts no liability for damage resulting from:

  • Sub-threshold leaks (below 1 l/min) whose nature prevented detection by the flow meter or by physical contact of the liquid with the probe/sensor.
  • Incorrect installation and positioning of the probe/sensor, its accidental or deliberate displacement (e.g. kicked or moved) by third parties, or the stream of water bypassing the probe/sensor (e.g. due to an uneven floor).
  • Mechanical jamming of the solenoid valve during its closing attempt (EZ-OFF) due to contaminants in the medium (e.g. sand, scale, limescale deposits), as well as damage to the solenoid valve control circuit (short circuit or open circuit) preventing it from being actuated correctly, caused e.g. by rodent activity or other mechanical factors.
  • Loss of AC power — the device operates in Fail-Safe NO (normally open) logic, which means the valve remains open in the event of a power failure. In critical or higher-risk buildings, the investor is obliged to provide an uninterruptible power supply (UPS) at their own expense.
  • Mechanical and electrical damage to the components of the RE control cabinet, as well as to the signal and power circuits connected to it.
  • Damage caused by electrical surges. The device's supply circuit must be fed from a main distribution board equipped with fully functional surge protection.
  • Interruptions in the building's protection during service or maintenance work. While system components are being removed, calibrated or repaired, water supply to the building is maintained by manually opening the service bypass. Any flood damage occurring while the system is disconnected and the building is supplied through an active bypass is not the manufacturer's responsibility.

05Risk management: leaks while Pause mode is active (Szychta / Domestic-Pause)

Hazard description: while Pause mode is active, the water volume counter is disabled by the system. During this time, protection relies solely on the dynamic flow threshold (detection of a main pipe burst) and the flood sensors.

If a connection hose starts leaking or bursts within this time window (e.g. while showering or doing household chores) and the leak produces a flow lower than the set dynamic threshold, the H-corePLC® & AQUA CONTRA system will not shut off the water supply on the basis of flow measurement.

Countermeasures and recommendations for the user:

  • Install flood sensors at critical points. During Pause, the only element capable of detecting a low-rate leak is a physical flood sensor (probe). Sensors should be placed at strategic points prone to failure (including under the shower/bath, next to washing machines, dishwashers, washbasins and in service shafts).
  • Awareness of limitations without a sensor. If there is no flood sensor at the point of failure, or it is incorrectly positioned, the leak will not be recognised by the system until Pause mode ends automatically and the system returns to Guard mode.
Pause mode blind spot. While Pause (Szychta) is active, the only and final protective barrier for the premises at flows below the dynamic threshold is the flood probe (sensor). This is a key technological area of risk management which the customer is strictly obliged to read and accept before purchasing the device.

06Installation and technical acceptance conditions

For the system to be deemed operational and covered by the warranty, the following are required:

  • Correct installation of the plumbing components according to the diagram (EZ solenoid valve, water meter, strainer, non-return valve, probe/sensor).
  • Construction and correct connection into the installation of a parallel service bypass, fitted with a manual shut-off valve sealed in the closed position.
  • Correct installation of the control cabinet (RE distribution board).
  • Completion of system acceptance tests with a positive result.
  • Signing of the commissioning and handover report confirming that the system operates in accordance with the operating and maintenance manual (DTR).

07Operational maintenance and service bypass

To ensure uninterrupted operation of the building (water supply) during maintenance work, component failures or service interruptions of the H-corePLC® system, the installation must be fitted with a hydraulic service bypass.

  • Operating status: during normal system operation, the manual bypass valve must always remain closed (securing it with a service seal is recommended).
  • Service procedure: opening the bypass and isolating the main line of the H-corePLC® & AQUA CONTRA system is permitted only for the duration of service procedures.
  • Risk awareness: the client/investor acknowledges that while the service bypass is open, the building is left entirely without the protection of the H-corePLC® & AQUA CONTRA system. Responsibility for supervising the installation during this period lies entirely with the technical staff or the building's user.

08Reference operating conditions (pressure)

The system's reference operating range is an installation working pressure of 3.0 to 4.5 bar. The client acknowledges that a drop in pipe pressure below 3.0 bar may prevent an emergency leak (e.g. a burst hose) from reaching the set flow threshold. This directly results in a longer system response time or a complete failure to detect the anomaly.

09Required water line equipment

To ensure reference operating conditions for the system, the water line must be fitted with a non-return valve and a strainer, installed upstream of the water meter and solenoid valve.

Failure to fit the above components in the water line releases the manufacturer from liability for the EZ solenoid valve failing to operate (not physically closing) when the system issues the EZ OFF signal (close solenoid valve).

10Required environmental conditions

Environmental conditions and location: the control cabinet (RE) must be installed in dry rooms, free from condensation, with a relative humidity of max. 90%. The RE must be protected from direct sunlight.

11Sub-threshold flow characteristics

Where the flow caused by a hose failure is below the dynamic detection threshold, the system protects the premises by means of the volume counter (V) and the leak probe.

For this reason, it is essential to optimise the volume threshold (V) so that this limit remains safe and acceptable in emergency conditions. Equally important is the correct positioning of the probe at the lowest point of water run-off, to ensure physical detection of the hazard before the total water volume limit is exceeded.

Deterministic protection
for your water system.
+48 000 000 000
kontakt@h-coreplc.pl
Koszalin
Systems
AQUA Contra — overview
AQUA Contra DIY
AQUA Contra BASIC
H-corePLC® — overview
H-corePLC® szychta
H-corePLC® office
PLC2 for risers
Academy
State of the art
Case study
Flow vs spot leak detector
FAQ
About us
Our history
Our mission
Why us
Service
Partnership
Book a presentation
Property developers
Wholesalers
Design offices
Installers
Terms of salePDF · version 1.0
Technical requirementsPDF · H-core specification
Privacy policyGDPR
H-corePLC®
© 2026 H-corePLC® & AQUA Contra
Terms · Privacy policy · Cookies